Pressure Rating vs Temperature

DRISCOPLEX® 6400 PE3608 HDPE PIPE 

The following chart provides maximum recommended working pressures for PE3608 / 3408  pipes & fittings for water, brine and dry natural gas gathering service at the indicated operating temperatures. 

Design (Working) Pressures for Water, Brine and Dry Natural Gas Gathering Service
(Class 1, Class 2 and non-Federally Regulated Areas)

Operating Temperature (p sig)

  Pipe DR 

73°F 

100°F 

 120°F 

140°F  

6

320

 250

 202

160 

 267

 208

 168

 134

 200

 156

 126

 100

11 

 160

 125

 101

 80

17 

 100

 78

 63

 50

21 

 80

 62

 50

 40

  1. Design (working) pressures are calculated in accordance with API 15LE specification.  A check should be made to determine if these pressures meet state and/or local codes.
  2. PE3608 pipes with different outside diameter, but the same DR have the same design (working) pressure ratings.
  3. Minimum pipe wall thickness is determined by dividing the pipe average outside diameter (OD) by the DR number.
  4. Meets or exceeds requirements of API 15LE, ASTM D2513 and PPI TR-4 Material Designation Code PE3608.
  5. ASTM D3350, Cell Classification PE345464C


DRISCOPLEX® 6400 PE4710 HDPE PIPE
 
The following chart provides maximum recommended working pressures for PE4710 / 3408  pipes & fittings for water, brine and dry natural gas gathering service at the indicated operating temperatures. 

Design (Working) Pressures for Water, Brine and Dry Natural Gas Gathering Service
(Class 1, Class 2 and non-Federally Regulated Areas)

Operating Temperature (p sig)

 Pipe DR

 73°F 

 100°F 

120°F 

 140°F 

 6

 403

 314

254

 202

 7

 336

 262

212

 168

 9

 252

 197

159

 126

 11

 202

 158

127

 101

 17

 126

 98

79

 63

 21

 101

 79

64

 51

  1. Design (working) pressures are calculated in accordance with API 15LE specification.  A check should be made to determine if these pressures meet state and/or local codes.
  2. PE4710 pipes with different outside diameter, but the same DR have the same design (working) pressure ratings.
  3. Minimum pipe wall thickness is determined by dividing the pipe average outside diameter (OD) by the DR number.
  4. Meets or exceeds requirements of API 15LE, ASTM D2513 and PPI TR-4 Material Designation Code PE4710.
  5. ASTM D3350, Cell Classification PE445474C